Front Oncol ; 13: 991952, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37114138

RESUMO

Introduction: To validate and evaluate the performance of knowledge-based treatment planning for Volumetric Modulated Arc Radiotherapy for post-mastectomy loco-regional radiotherapy. Material and methods: Two knowledge-based planning (KBP) models for different dose prescriptions were built using the Eclipse RapidPlanTM v 16.1 (Varian Medical Systems, Palo Alto, USA) utilising the plans of previously treated patients with left-sided breast cancer who had undergone irradiation of the left chest wall, internal mammary nodal (IMN) region and supra-clavicular fossa (SCF). Plans of 60 and 73 patients were used to generate the KBP models for the prescriptions of 40 Gy in 15 fractions and 26 Gy in 5 fractions, respectively. A blinded review of all the clinical plans (CLI) and KBPs was done by two experienced radiation oncology consultants. Statistical analysis of the two groups was also done using the standard two-tailed paired t-test or Wilcoxon signed rank test, and p<0.05 was considered significant. Results: A total of 20 metrics were compared. The KBPs were found to be either better (6/20) or comparable (10/20) to the CLIs for both the regimens. Dose to heart, contralateral breast,contralateral lung were either better or comparable in the KBP plans except of ipsilateral lung. Mean dose (Gy) for the ipsilateral lung are significantly (p˂0.001) higher in KBP though the values were acceptable clinically. Plans were of similar quality as per the result of the blinded review which was conducted by slice-by-slice evaluation of dose distribution for target coverage, overdose volume and dose to the OARs. However, it was also observed that treatment times in terms of monitoring units (MUs) and complexity indices are more in CLIs as compared with KBPs (p<0.001). Discussion: KBP models for left-sided post-mastectomy loco-regional radiotherapy were developed and validated for clinical use. These models improved the efficiency of treatment delivery as well as work flow for VMAT planning involving both moderately hypo fractionated and ultra-hypo fractionated radiotherapy regimens.

2.
J Med Phys ; 47(2): 145-151, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36212209

RESUMO

Background: This study aims to design an indigenous baseplate (ID baseplate) that is economically viable and dosimetrically comparable for radiotherapy patient treatment. An ID baseplate was designed and manufactured using wood plastic composition materials that are readily available in the market and were compared dosimetrically with the commercially available carbon fiber baseplate (CF baseplate). Materials and Methods: Surface dose and beam attenuation properties of both the baseplates (ID and CF) were measured using a parallel plate chamber and compared with the dose calculated from the treatment planning system (TPS). Separate computer tomography images of both the baseplates were acquired by placing solid water phantoms. These images were used for surface dose calculation in the TPS and were validated with experimental measurements. Proper densities were assigned to the couch and baseplates to avoid uncertainties in dose calculations. All measurements were performed at field sizes 10 cm × 10 cm for 6 MV and 15 MV photon beams. Results: The percentage surface dose measured for the ID baseplate and CF baseplate was found to be matching for 6 MV beam (98.2% and 97%, respectively); however, for the 15 MV beam, the ID baseplate showed a higher surface dose of 98.6% compared to CF baseplate (87.4%). For the ID baseplate, the percentage difference in the surface dose between that TPS calculated value and the measured values were 1.6% and 1.4% for 6MV and 15MV, respectively. The ID baseplate showed higher beam attenuation than the CF baseplate by 2.2% for the 6MV beam and 3.4% for the 15MV beam when proper electron densities were not assigned. The difference between the TPS calculated dose and delivered dose was achieved within 3% after assigning proper electron density to the couch and baseplate. Conclusions: The ID baseplate has shown acceptable dosimetric results and can be an economically viable alternative to the commercially available CF baseplates. The manufacturing cost of the ID baseplate was ten times cheaper than the CF baseplate.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...